齒輪箱的正常壓力范圍為1.08~1.47MPa,壓力低于1.08MPa。認為變速油壓太低,這將導(dǎo)致45方自動上料攪拌車的驅(qū)動力不足,整機弱,齒輪不起動。
The normal pressure range of gearbox is 1.08 ~ 1.47mpa, and the pressure is lower than 1.08mpa. It is considered that the variable speed oil pressure is too low, which will lead to insufficient driving force of 4-5 square automatic feeding mixer, weak whole machine and no gear start.
減壓閥的功能是通過壓力調(diào)節(jié)彈簧將較高的輸入壓力調(diào)節(jié)到規(guī)定的輸出壓力,并確保輸出壓力的平衡。一旦減壓閥的壓力調(diào)節(jié)彈簧損壞,變速箱將不能保證正常的輸出壓力。
The function of the pressure reducing valve is to adjust the higher input pressure to the specified output pressure through the pressure regulating spring and ensure the balance of the output pressure. Once the pressure regulating spring of the pressure reducing valve is damaged, the transmission will not guarantee the normal output pressure.
其次,壓力調(diào)節(jié)器沒有適當(dāng)調(diào)整
Secondly, the pressure regulator is not properly adjusted
壓力調(diào)節(jié)閥通過壓力調(diào)節(jié)閥芯控制變速器的輸出壓力。如果輸出壓力太小,變速箱油壓將太低。
The pressure regulating valve controls the output pressure of the transmission through the pressure regulating valve core. If the output pressure is too low, the transmission oil pressure will be too low.
三是管道油封嚴重漏油。
Third, the oil seal of the pipeline leaks seriously.
檢查變速箱油盤到變速箱泵吸入管路是否泄漏。如果發(fā)現(xiàn)漏油,請修理或更換新線路。
Check the transmission oil pan to transmission pump suction line for leakage. If oil leakage is found, repair or replace the line.
如何使用45方自動上料攪拌車散熱器
How to use the radiator of 4-5 square automatic feeding mixer truck
1.備用散熱器的有效環(huán)境應(yīng)保持通風(fēng)干燥。
1. The effective environment of the standby radiator shall be ventilated and dry.
2.軟化處理后,建議使用軟水和硬水,以避免散熱器內(nèi)部堵塞和水垢的產(chǎn)生。
2. After softening treatment, it is recommended to use soft water and hard water to avoid blockage and scale in the radiator.
3.在冬季,為了防止結(jié)冰引起的核心結(jié)冰,如果45方自動上料攪拌車長時間停放或間接停止,應(yīng)使用水箱蓋和排水開關(guān)排出所有水。
3. In winter, in order to prevent core icing caused by icing, if the 4-5-party automatic loading mixer stops for a long time or stops indirectly, all water shall be discharged by using the water tank cover and drainage switch.
4.水位計應(yīng)每3個月清洗一次或根據(jù)實際情況清洗,應(yīng)取出部件并用溫水和無腐蝕性清洗劑清洗。
4. The water level gauge shall be cleaned every 3 months or according to the actual situation. The parts shall be taken out and cleaned with warm water and non corrosive cleaning agent.
5.當(dāng)散熱器完全排空并重新注滿時,應(yīng)將發(fā)動機缸體的排水開關(guān)扭開,當(dāng)有水流出時,再將其關(guān)閉以避免起泡。
5. When the radiator is completely drained and refilled, first turn on the drain switch of the engine block, and then close it when water flows out to avoid foaming.
6.在日常使用中應(yīng)隨時檢查水位,冷卻后停止水。加水時,慢慢打開水箱蓋,操作人員的身體應(yīng)盡可能遠離供水口,以防止高壓蒸汽油噴出而導(dǎo)致灼傷。
6. The water level shall be checked at any time during daily use, and the water shall be stopped after cooling. When adding water, slowly open the water tank cover, and the operator's body should be as far away from the water supply port as possible to prevent burns caused by the ejection of high-pressure steam gasoline.
7.散熱器不應(yīng)與任何酸,堿或其他腐蝕性物質(zhì)接觸。
7. The radiator shall not contact with any acid, alkali or other corrosive substances.
8.在使用防凍液時,為避免散熱器的腐蝕,請務(wù)必使用常規(guī)廠家生產(chǎn)的長期防銹防凍液,并符合標(biāo)準。
8. When using antifreeze, in order to avoid the corrosion of radiator, please be sure to use the long-term anti rust antifreeze produced by conventional manufacturers and comply with national standards.
9.根據(jù)實際情況,用戶應(yīng)徹底清潔散熱器一三個月。清潔時,沿反向進氣口側(cè)用清水沖洗。
9. According to the actual situation, the user should thoroughly clean the radiator for one to three months. When cleaning, flush with clean water along the reverse air inlet side.
10.在安裝散熱器時,請勿損壞散熱片(切片)和保險杠散熱片,以確保散熱和密封。
10. When installing the radiator, do not damage the heat sink (slice) and bumper heat sink to ensure heat dissipation and sealing.
我們一直在堅持分享的路上全自動混凝土攪拌車http://www.qirongguanjia.cn真正為您您所需要的問題.
We have been insisting on sharing the road with full-automatic concrete mixer http://www.qirongguanjia.cn Truly solve the problems you need